Recipient information | Input |
---|---|
Total number of customers served by utility / utilities supporting the project | 3,578,188 |
Total number of residential customers served by utility / utilities supporting the project | 3,040,024 |
Total number of commercial customers served by utility / utilities supporting the project | 532,825 |
Total number of industrial customers served by utility / utilities supporting the project | 0 |
Total number of distribution circuits within utility service territory | 2,513 |
Total number of distribution substations | 130 |
Portion of distribution system with SCADA prior to SGIG/SGD program | 0 |
Portion of distribution system with distribution automation (DA) prior to SGIG/SGD program | 0 |
Electric distribution system | % | Description |
---|---|---|
Portion of distribution system with SCADA due to SGIG/SGD program | 39.00% | Calculation: # of feeders with SCADA equipment / Total # system feeders. Both the numerator and denominator figures include ConEdison + Orange & Rockland affiliate. |
Portion of distribution system with DA due to SGIG/SGD program | 37.00% | Calculation: # of feeders with DA equipment / Total # system feeders. Both the numerator and denominator figures include ConEdison + Orange & Rockland affiliate. |
DA devices installed and operational | Quantity* | Description | Cost |
---|---|---|---|
Automated feeder switches | 797 | Deployed DA devices include sectionalizing switches, capacitors, load tap changers, regulators and reclosers. These all become fully operational on a rolling basis, dependent upon individual project schedules. In addition, new wireless mesh based on unlicensed 900Mhz is being deployed in Staten Island. | $124,307,558 |
Automated capacitors | 449 | $17,966,670 | |
Automated regulators | 111 | $0 | |
Feeder monitors | 617 | $60,483,314 | |
Remote fault indicators | 1,851 | $0 | |
Transformer monitors (line) | 17,401 | $0 | |
Smart relays | 205 | ||
Fault current limiter | 0 | $0 | |
Other devices | 324 | $0 |
SCADA and DA communications network | Cost |
---|---|
Communications equipment and SCADA | $35,359,650 |
Distribution management systems integration | Integrated | Description |
---|---|---|
AMI | No | |
Outage management system | No | |
Distributed energy resource interface | No | |
Other | No |
Distribution automation features / functionality | Function enabled | Description |
---|---|---|
Fault location, isolation and service restoration (FLISR) | No | The autoloop configuration will allow for the isolation of a fault and also determine the location of the fault utilizing a proprietary technology. Overhead reclosers installed on autoloops automatically identify and restore unfaulted portions. Full operation of the enhanced autoloop will involve 24 feeders. |
Voltage optimization | Yes | A software application installed on Con Edison’s SCADA control room system will automate and enhance remote 4kV secondary bus voltage regulation at both the unit station and grid level. The VVC application shall remotely and automatically maintain unit station 4kV bus voltage at a desired value based on station specific load voltage schedules. Unit station 4kV bus voltage regulation will be accomplished through load tap changer (LTC) control. LTCs will affect 620 of 675 4kv feeders. |
Feeder peak load management | Yes | Switchable capacitor banks will be installed to improve the performance of the non-network distribution system by supplying local volt-ampere-reactive (VAR) power close to the 4kV feeder load. Switchable capacitors installed near the feeder load provide the reactive current to the load and reduce total reactive power flow. The resulting benefits include: loss reduction, power factor correction, improved feeder voltage profile, maximized feeder capacity, and deferment of load relief projects. Capacitors will be installed on 285 of 675 4kv feeders on the system. |
Microgrids | No | |
Other functions | No |